3      Copyright (C) Dean Camera, 2014. 
   5   dean [at] fourwalledcubicle [dot] com 
  10     Front-end configuration app for the TempDataLogger project. This script 
  11     configures the logger to the current system time and date, with a user 
  12     defined logging interval. 
  14     The logging interval should be specified in milliseconds and is rounded to 
  18         python temp_log_config.py <Log_Interval> 
  21         python temp_log_config.py 500 
  23     Requires the pywinusb library (https://pypi.python.org/pypi/pywinusb/). 
  27 from datetime 
import datetime
 
  28 import pywinusb
.hid 
as hid
 
  30 # Generic HID device VID, PID and report payload length (length is increased 
  31 # by one to account for the Report ID byte that must be pre-pended) 
  37 def get_hid_device_handle(): 
  38     hid_device_filter 
= hid
.HidDeviceFilter(vendor_id
=device_vid
, 
  39                                             product_id
=device_pid
) 
  41     valid_hid_devices 
= hid_device_filter
.get_devices() 
  43     if len(valid_hid_devices
) is 0: 
  46         return valid_hid_devices
[0] 
  49 def configure_temp_log_device(device
, time_date
, log_interval_500ms
): 
  50     # Report data for the demo is the report ID (always zero) 
  53     # Followed by the time/date data 
  54     report_data
.extend([time_date
.hour
, time_date
.minute
, 
  55                         time_date
.second
, time_date
.day
, 
  56                         time_date
.month
, time_date
.year 
- 2000]) 
  58     # Lastly the log interval in 500ms units of time 
  59     report_data
.extend([log_interval_500ms
]) 
  61     # Zero-extend the array to the length the report should be 
  62     report_data
.extend([0] * (report_length 
- len(report_data
))) 
  64     # Send the generated report to the device 
  65     device
.send_output_report(report_data
) 
  68 def main(time_date
, log_interval_500ms
): 
  69     hid_device 
= get_hid_device_handle() 
  71     if hid_device 
is None: 
  72         print("No valid HID device found.") 
  78         print("Connected to device 0x%04X/0x%04X - %s [%s]" % 
  79               (hid_device
.vendor_id
, hid_device
.product_id
, 
  80                hid_device
.product_name
, hid_device
.vendor_name
)) 
  82         configure_temp_log_device(hid_device
, time_date
, log_interval_500ms
) 
  84         print("Time/Date is now set to %s" % time_date
) 
  85         print("Log interval is now set to every %0.1fs" % 
(log_interval_500ms 
* (500.0 / 1000.0))) 
  91 if __name__ 
== '__main__': 
  92     time_date 
= datetime
.now() 
  93     log_interval_500ms 
= (int(sys
.argv
[1]) / 500) if len(sys
.argv
) > 1 else 2 
  95     # Clamp the log interval to the allowable range 
  96     log_interval_500ms 
= max(log_interval_500ms
, 0x01) 
  97     log_interval_500ms 
= min(log_interval_500ms
, 0xFF) 