3 * This file contains special DoxyGen information for the generation of the main page and other special
4 * documentation pages. It is not a project source file.
7 /** \mainpage Temperature Datalogger Project
9 * \section SSec_Compat Demo Compatibility:
11 * The following list indicates what microcontrollers are compatible with this demo.
15 * - Series 4 USB AVRs (with >16KB of FLASH)
17 * \section SSec_Info USB Information:
19 * The following table gives a rundown of the USB utilization of this demo.
23 * <td><b>USB Mode:</b></td>
27 * <td><b>USB Classes:</b></td>
28 * <td>Mass Storage Device</td>
29 * <td>Human Interface Device</td>
32 * <td><b>USB Subclasses:</b></td>
33 * <td>Bulk-Only Transport</td>
34 * <td>Keyboard Subclass</td>
37 * <td><b>Relevant Standards:</b></td>
38 * <td>USBIF Mass Storage Standard</td>
39 * <td>USB Bulk-Only Transport Standard</td>
40 * <td>SCSI Primary Commands Specification</td>
41 * <td>SCSI Block Commands Specification</td>
42 * <td>USBIF HID Specification, USBIF HID Usage Tables</td>
45 * <td><b>Usable Speeds:</b></td>
46 * <td>Full Speed Mode</td>
50 * \section SSec_Description Project Description:
52 * Temperature Data Logger project. This project is a very basic USB data logger for the current temperature as reported by
53 * the board's temperature sensor, writing the temperature to a file stored on the board's Dataflash in a FAT filesystem
54 * each time a specified interval elapses. When inserted into a PC, the datalogger will appear as a standard USB Mass Storage
55 * device with a single text file, which contains the logged data. Files are named according to the current date when the
58 * A DS1307 or compatible RTC IC is designed to be attached to the AVR's TWI bus, for the management of timestamps on the
59 * sampled data. This project will not function correctly if the RTC chip is omitted unless the DUMMY_RTC compile time token
60 * is specified - see \ref SSec_Options.
62 * Due to the host's need for exclusive access to the filesystem, the device will not log samples while connected to a host.
63 * For the logger to store data, the Dataflash must first be formatted by the host so that it contains a valid FAT filesystem.
65 * \section SSec_Options Project Options
67 * The following defines can be found in this demo, which can control the demo behaviour when defined, or changed in value.
71 * <td><b>Define Name:</b></td>
72 * <td><b>Location:</b></td>
73 * <td><b>Description:</b></td>
77 * <td>Makefile CDEFS</td>
78 * <td>When a DS1307 RTC chip is not fitted, this token can be defined to make the demo assume a 1/1/1 01:01:01 date/time
79 * stamp at all times, effectively transforming the project into a basic data logger with no specified sample times.</td>