+                        *  \return A value from the \ref Pipe_Stream_RW_ErrorCodes_t enum.\r
+                        */\r
+                       uint8_t Pipe_Discard_Stream(uint16_t Length,\r
+                                                   uint16_t* const BytesProcessed);\r
+\r
+                       /** Writes a given number of zeroed bytes to the pipe, sending full pipe packets from the host to the device\r
+                        *  as needed. The last packet is not automatically sent once the remaining bytes has been written; the\r
+                        *  user is responsible for manually discarding the last packet from the device via the \ref Pipe_ClearOUT() macro.\r
+                        *\r
+                        *  If the BytesProcessed parameter is \c NULL, the entire stream transfer is attempted at once, failing or\r
+                        *  succeeding as a single unit. If the BytesProcessed parameter points to a valid storage location, the transfer\r
+                        *  will instead be performed as a series of chunks. Each time the pipe bank becomes full while there is still data\r
+                        *  to process (and after the current packet transmission has been initiated) the BytesProcessed location will be\r
+                        *  updated with the total number of bytes processed in the stream, and the function will exit with an error code of\r
+                        *  \ref PIPE_RWSTREAM_IncompleteTransfer. This allows for any abort checking to be performed in the user code - to\r
+                        *  continue the transfer, call the function again with identical parameters and it will resume until the BytesProcessed\r
+                        *  value reaches the total transfer length.\r
+                        *\r
+                        *  <b>Single Stream Transfer Example:</b>\r
+                        *  \code\r
+                        *  uint8_t ErrorCode;\r
+                        *\r
+                        *  if ((ErrorCode = Pipe_Null_Stream(512, NULL)) != PIPE_RWSTREAM_NoError)\r
+                        *  {\r
+                        *       // Stream failed to complete - check ErrorCode here\r
+                        *  }\r
+                        *  \endcode\r
+                        *\r
+                        *  <b>Partial Stream Transfers Example:</b>\r
+                        *  \code\r
+                        *  uint8_t  ErrorCode;\r
+                        *  uint16_t BytesProcessed;\r
+                        *\r
+                        *  BytesProcessed = 0;\r
+                        *  while ((ErrorCode = Pipe_Null_Stream(512, &BytesProcessed)) == PIPE_RWSTREAM_IncompleteTransfer)\r
+                        *  {\r
+                        *      // Stream not yet complete - do other actions here, abort if required\r
+                        *  }\r
+                        *\r
+                        *  if (ErrorCode != PIPE_RWSTREAM_NoError)\r
+                        *  {\r
+                        *      // Stream failed to complete - check ErrorCode here\r
+                        *  }\r
+                        *  \endcode\r
+                        *\r
+                        *  \note The pipe token is set automatically, thus this can be used on bi-directional pipes directly without\r
+                        *        having to explicitly change the data direction with a call to \ref Pipe_SetPipeToken().\r
+                        *\r
+                        *  \param[in] Length          Number of zero bytes to write via the currently selected pipe.\r
+                        *  \param[in] BytesProcessed  Pointer to a location where the total number of bytes already processed should\r
+                        *                             updated, \c NULL if the entire stream should be processed at once.\r