* Functions, macros, variables, enums and types related to data reading and writing from and to endpoints.\r
*/\r
\r
+/** \ingroup Group_EndpointRW \r
+ * @defgroup Group_EndpointPrimitiveRW Read/Write of Primitive Data Types\r
+ *\r
+ * Functions, macros, variables, enums and types related to data reading and writing of primitive data types\r
+ * from and to endpoints.\r
+ */ \r
+\r
+/** \ingroup Group_EndpointRW \r
+ * @defgroup Group_EndpointStreamRW Read/Write of Multi-Byte Streams\r
+ *\r
+ * Functions, macros, variables, enums and types related to data reading and writing of data streams from\r
+ * and to endpoints.\r
+ */ \r
+\r
/** @defgroup Group_EndpointPacketManagement Endpoint Packet Management\r
*\r
* Functions, macros, variables, enums and types related to packet management of endpoints.\r
\r
/* Includes: */\r
#include <avr/io.h>\r
+ #include <avr/pgmspace.h>\r
+ #include <avr/eeprom.h>\r
#include <stdbool.h>\r
\r
#include "../../../Common/Common.h"\r
\r
/** Maximum size in bytes of a given endpoint.\r
*\r
- * \param n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)\r
+ * \param[in] n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)\r
*/ \r
#define ENDPOINT_MAX_SIZE(n) _ENDPOINT_GET_MAXSIZE(n)\r
\r
/** Indicates if the given endpoint supports double banking.\r
*\r
- * \param n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)\r
+ * \param[in] n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)\r
*/ \r
#define ENDPOINT_DOUBLEBANK_SUPPORTED(n) _ENDPOINT_GET_DOUBLEBANK(n)\r
\r
#if !defined(CONTROL_ONLY_DEVICE)\r
- #if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER) || defined(__DOXYGEN__)\r
+ #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR) || defined(__DOXYGEN__)\r
/** Total number of endpoints (including the default control endpoint at address 0) which may\r
* be used in the device. Different USB AVR models support different amounts of endpoints,\r
* this value reflects the maximum number of endpoints for the currently selected AVR model.\r
* Any endpoint operations which do not require the endpoint number to be indicated will operate on\r
* the currently selected endpoint.\r
*\r
- * \param EndpointNumber Endpoint number to select\r
+ * \param[in] EndpointNumber Endpoint number to select\r
*/\r
static inline void Endpoint_SelectEndpoint(uint8_t EndpointNumber);\r
\r
/** Resets the endpoint bank FIFO. This clears all the endpoint banks and resets the USB controller's\r
* In and Out pointers to the bank's contents.\r
*\r
- * \param EndpointNumber Endpoint number whose FIFO buffers are to be reset\r
+ * \param[in] EndpointNumber Endpoint number whose FIFO buffers are to be reset\r
*/\r
static inline void Endpoint_ResetFIFO(uint8_t EndpointNumber);\r
\r
/** Determines if the specified endpoint number has interrupted (valid only for INTERRUPT type\r
* endpoints).\r
*\r
- * \param EndpointNumber Index of the endpoint whose interrupt flag should be tested\r
+ * \param[in] EndpointNumber Index of the endpoint whose interrupt flag should be tested\r
*\r
* \return Boolean true if the specified endpoint has interrupted, false otherwise\r
*/\r
*/\r
static inline uint8_t Endpoint_GetEndpointDirection(void);\r
#else\r
- #if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER) || defined(__DOXYGEN__)\r
+ #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR) || defined(__DOXYGEN__)\r
#define Endpoint_BytesInEndpoint() UEBCX\r
#else\r
#define Endpoint_BytesInEndpoint() UEBCLX\r
\r
/** Enum for the possible error return codes of the Endpoint_*_Stream_* functions.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*/\r
enum Endpoint_Stream_RW_ErrorCodes_t\r
{\r
ENDPOINT_RWSTREAM_EndpointStalled = 1, /**< The endpoint was stalled during the stream\r
* transfer by the host or device.\r
*/\r
- ENDPOINT_RWSTREAM_DeviceDisconnected = 1, /**< Device was disconnected from the host during\r
+ ENDPOINT_RWSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during\r
* the transfer.\r
*/\r
- ENDPOINT_RWSTREAM_Timeout = 2, /**< The host failed to accept or send the next packet\r
+ ENDPOINT_RWSTREAM_Timeout = 3, /**< The host failed to accept or send the next packet\r
* within the software timeout period set by the\r
* \ref USB_STREAM_TIMEOUT_MS macro.\r
*/\r
- ENDPOINT_RWSTREAM_CallbackAborted = 3, /**< Indicates that the stream's callback function\r
+ ENDPOINT_RWSTREAM_CallbackAborted = 4, /**< Indicates that the stream's callback function\r
* aborted the transfer early.\r
*/\r
};\r
\r
/** Enum for the possible error return codes of the Endpoint_*_Control_Stream_* functions..\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*/\r
enum Endpoint_ControlStream_RW_ErrorCodes_t\r
{\r
ENDPOINT_RWCSTREAM_NoError = 0, /**< Command completed successfully, no error. */\r
ENDPOINT_RWCSTREAM_HostAborted = 1, /**< The aborted the transfer prematurely. */\r
+ ENDPOINT_RWCSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during\r
+ * the transfer.\r
+ */\r
};\r
\r
/* Inline Functions: */\r
/** Reads one byte from the currently selected endpoint's bank, for OUT direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
* \return Next byte in the currently selected endpoint's FIFO buffer\r
*/\r
\r
/** Writes one byte from the currently selected endpoint's bank, for IN direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
- * \param Byte Next byte to write into the the currently selected endpoint's FIFO buffer\r
+ * \param[in] Byte Next byte to write into the the currently selected endpoint's FIFO buffer\r
*/\r
static inline void Endpoint_Write_Byte(const uint8_t Byte) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Write_Byte(const uint8_t Byte)\r
\r
/** Discards one byte from the currently selected endpoint's bank, for OUT direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*/\r
static inline void Endpoint_Discard_Byte(void) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Discard_Byte(void)\r
/** Reads two bytes from the currently selected endpoint's bank in little endian format, for OUT\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
* \return Next word in the currently selected endpoint's FIFO buffer\r
*/\r
/** Reads two bytes from the currently selected endpoint's bank in big endian format, for OUT\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
* \return Next word in the currently selected endpoint's FIFO buffer\r
*/\r
/** Writes two bytes to the currently selected endpoint's bank in little endian format, for IN\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
- * \param Word Next word to write to the currently selected endpoint's FIFO buffer\r
+ * \param[in] Word Next word to write to the currently selected endpoint's FIFO buffer\r
*/\r
static inline void Endpoint_Write_Word_LE(const uint16_t Word) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Write_Word_LE(const uint16_t Word)\r
/** Writes two bytes to the currently selected endpoint's bank in big endian format, for IN\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
- * \param Word Next word to write to the currently selected endpoint's FIFO buffer\r
+ * \param[in] Word Next word to write to the currently selected endpoint's FIFO buffer\r
*/\r
static inline void Endpoint_Write_Word_BE(const uint16_t Word) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Write_Word_BE(const uint16_t Word)\r
\r
/** Discards two bytes from the currently selected endpoint's bank, for OUT direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*/\r
static inline void Endpoint_Discard_Word(void) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Discard_Word(void)\r
/** Reads four bytes from the currently selected endpoint's bank in little endian format, for OUT\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
* \return Next double word in the currently selected endpoint's FIFO buffer\r
*/\r
/** Reads four bytes from the currently selected endpoint's bank in big endian format, for OUT\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
* \return Next double word in the currently selected endpoint's FIFO buffer\r
*/\r
/** Writes four bytes to the currently selected endpoint's bank in little endian format, for IN\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
- * \param DWord Next double word to write to the currently selected endpoint's FIFO buffer\r
+ * \param[in] DWord Next double word to write to the currently selected endpoint's FIFO buffer\r
*/\r
static inline void Endpoint_Write_DWord_LE(const uint32_t DWord) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Write_DWord_LE(const uint32_t DWord)\r
/** Writes four bytes to the currently selected endpoint's bank in big endian format, for IN\r
* direction endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*\r
- * \param DWord Next double word to write to the currently selected endpoint's FIFO buffer\r
+ * \param[in] DWord Next double word to write to the currently selected endpoint's FIFO buffer\r
*/\r
static inline void Endpoint_Write_DWord_BE(const uint32_t DWord) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Write_DWord_BE(const uint32_t DWord)\r
\r
/** Discards four bytes from the currently selected endpoint's bank, for OUT direction endpoints. \r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointPrimitiveRW\r
*/\r
static inline void Endpoint_Discard_DWord(void) ATTR_ALWAYS_INLINE;\r
static inline void Endpoint_Discard_DWord(void)\r
#endif\r
\r
/* Function Prototypes: */\r
+ #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
+ #define _CALLBACK_PARAM , StreamCallbackPtr_t Callback\r
+ #else\r
+ #define _CALLBACK_PARAM \r
+ #endif\r
+ \r
/** Configures the specified endpoint number with the given endpoint type, direction, bank size\r
* and banking mode. Endpoints should be allocated in ascending order by their address in the\r
- * device (i.e. endpoint 1 should be configured before endpoint 2 and so on).\r
+ * device (i.e. endpoint 1 should be configured before endpoint 2 and so on) to prevent fragmentation\r
+ * of the USB FIFO memory.\r
*\r
* The endpoint type may be one of the EP_TYPE_* macros listed in LowLevel.h and the direction\r
* may be either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.\r
*\r
* The banking mode may be either \ref ENDPOINT_BANK_SINGLE or \ref ENDPOINT_BANK_DOUBLE.\r
*\r
- * The success of this routine can be determined via the \ref Endpoint_IsConfigured() macro.\r
+ * \note The default control endpoint does not have to be manually configured, as it is automatically\r
+ * configured by the library internally.\r
*\r
* \note This routine will select the specified endpoint, and the endpoint will remain selected\r
* once the routine completes regardless of if the endpoint configuration succeeds.\r
bool Endpoint_ConfigureEndpoint(const uint8_t Number, const uint8_t Type, const uint8_t Direction,\r
const uint16_t Size, const uint8_t Banks);\r
\r
- #if !defined(CONTROL_ONLY_DEVICE)\r
-\r
/** Spinloops until the currently selected non-control endpoint is ready for the next packet of data\r
* to be read or written to it.\r
*\r
* \return A value from the \ref Endpoint_WaitUntilReady_ErrorCodes_t enum.\r
*/\r
uint8_t Endpoint_WaitUntilReady(void);\r
+ \r
+ /** Completes the status stage of a control transfer on a CONTROL type endpoint automatically,\r
+ * with respect to the data direction. This is a convenience function which can be used to\r
+ * simplify user control request handling.\r
+ */\r
+ void Endpoint_ClearStatusStage(void);\r
\r
/** Reads and discards the given number of bytes from the endpoint from the given buffer,\r
* discarding fully read packets from the host as needed. The last packet is not automatically\r
*\r
* \note This routine should not be used on CONTROL type endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Length Number of bytes to send via the currently selected endpoint.\r
- * \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
*\r
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Discard_Stream(uint16_t Length\r
- #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
- , StreamCallbackPtr_t Callback\r
- #endif\r
- );\r
+ uint8_t Endpoint_Discard_Stream(uint16_t Length _CALLBACK_PARAM);\r
\r
/** Writes the given number of bytes to the endpoint from the given buffer in little endian,\r
* sending full packets to the host as needed. The last packet filled is not automatically sent;\r
*\r
* \note This routine should not be used on CONTROL type endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the source data buffer to read from.\r
- * \param Length Number of bytes to read for the currently selected endpoint into the buffer.\r
- * \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
*\r
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Write_Stream_LE(const void* Buffer, uint16_t Length\r
- #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
- , StreamCallbackPtr_t Callback\r
- #endif\r
- ) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Write_Stream_LE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** EEPROM buffer source version of \ref Endpoint_Write_Stream_LE.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_EStream_LE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** FLASH buffer source version of \ref Endpoint_Write_Stream_LE.\r
+ *\r
+ * \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_PStream_LE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
\r
/** Writes the given number of bytes to the endpoint from the given buffer in big endian,\r
* sending full packets to the host as needed. The last packet filled is not automatically sent;\r
*\r
* \note This routine should not be used on CONTROL type endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the source data buffer to read from.\r
- * \param Length Number of bytes to read for the currently selected endpoint into the buffer.\r
- * \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
*\r
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Write_Stream_BE(const void* Buffer, uint16_t Length\r
- #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
- , StreamCallbackPtr_t Callback\r
- #endif\r
- ) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Write_Stream_BE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** EEPROM buffer source version of \ref Endpoint_Write_Stream_BE.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_EStream_BE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** FLASH buffer source version of \ref Endpoint_Write_Stream_BE.\r
+ *\r
+ * \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_PStream_BE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
\r
/** Reads the given number of bytes from the endpoint from the given buffer in little endian,\r
* discarding fully read packets from the host as needed. The last packet is not automatically\r
*\r
* \note This routine should not be used on CONTROL type endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the destination data buffer to write to.\r
- * \param Length Number of bytes to send via the currently selected endpoint.\r
- * \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
*\r
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Read_Stream_LE(void* Buffer, uint16_t Length\r
- #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
- , StreamCallbackPtr_t Callback\r
- #endif\r
- ) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Read_Stream_LE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
\r
+ /** EEPROM buffer source version of \ref Endpoint_Read_Stream_LE.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to, located in EEPROM memory space.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Read_EStream_LE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
+ \r
/** Reads the given number of bytes from the endpoint from the given buffer in big endian,\r
* discarding fully read packets from the host as needed. The last packet is not automatically\r
* discarded once the remaining bytes has been read; the user is responsible for manually\r
*\r
* \note This routine should not be used on CONTROL type endpoints.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the destination data buffer to write to.\r
- * \param Length Number of bytes to send via the currently selected endpoint.\r
- * \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
*\r
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Read_Stream_BE(void* Buffer, uint16_t Length\r
- #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)\r
- , StreamCallbackPtr_t Callback\r
- #endif\r
- ) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Read_Stream_BE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
\r
- #endif\r
+ /** EEPROM buffer source version of \ref Endpoint_Read_Stream_BE.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to, located in EEPROM memory space.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback\r
+ *\r
+ * \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Read_EStream_BE(void* Buffer, uint16_t Length _CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);\r
\r
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,\r
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared\r
* in both failure and success states; the user is responsible for manually clearing the setup OUT to\r
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.\r
*\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
* \note This routine should only be used on CONTROL type endpoints.\r
*\r
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
* together; i.e. the entire stream data must be read or written at the one time.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the source data buffer to read from.\r
- * \param Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
*\r
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Write_Control_Stream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Write_Control_Stream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** EEPROM buffer source version of Endpoint_Write_Control_Stream_LE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
+ *\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_Control_EStream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_LE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
+ *\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_Control_PStream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
\r
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,\r
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared\r
* in both failure and success states; the user is responsible for manually clearing the setup OUT to\r
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.\r
*\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
* \note This routine should only be used on CONTROL type endpoints.\r
*\r
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
* together; i.e. the entire stream data must be read or written at the one time.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_Control_Stream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** EEPROM buffer source version of \ref Endpoint_Write_Control_Stream_BE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
*\r
- * \param Buffer Pointer to the source data buffer to read from.\r
- * \param Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
*\r
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
*/\r
- uint8_t Endpoint_Write_Control_Stream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+ uint8_t Endpoint_Write_Control_EStream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
+ /** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_BE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
+ *\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[in] Buffer Pointer to the source data buffer to read from.\r
+ * \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Write_Control_PStream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
\r
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,\r
* discarding fully read packets from the host as needed. The device IN acknowledgement is not\r
* automatically sent after success or failure states; the user is responsible for manually sending the\r
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.\r
*\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
* \note This routine should only be used on CONTROL type endpoints.\r
*\r
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
* together; i.e. the entire stream data must be read or written at the one time.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the destination data buffer to write to.\r
- * \param Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
*\r
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
*/\r
uint8_t Endpoint_Read_Control_Stream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
\r
+ /** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_LE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
+ *\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Read_Control_EStream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);\r
+\r
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,\r
* discarding fully read packets from the host as needed. The device IN acknowledgement is not\r
* automatically sent after success or failure states; the user is responsible for manually sending the\r
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.\r
*\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
* \note This routine should only be used on CONTROL type endpoints.\r
*\r
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
* together; i.e. the entire stream data must be read or written at the one time.\r
*\r
- * \ingroup Group_EndpointRW\r
+ * \ingroup Group_EndpointStreamRW\r
*\r
- * \param Buffer Pointer to the destination data buffer to write to.\r
- * \param Length Number of bytes to send via the currently selected endpoint.\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
*\r
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
*/\r
uint8_t Endpoint_Read_Control_Stream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1); \r
\r
+ /** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_BE.\r
+ *\r
+ * \note This function automatically clears the control transfer's status stage. Do not manually attempt\r
+ * to clear the status stage when using this routine in a control transaction.\r
+ *\r
+ * \note This routine should only be used on CONTROL type endpoints.\r
+ *\r
+ * \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained\r
+ * together; i.e. the entire stream data must be read or written at the one time.\r
+ *\r
+ * \ingroup Group_EndpointStreamRW\r
+ *\r
+ * \param[out] Buffer Pointer to the destination data buffer to write to.\r
+ * \param[in] Length Number of bytes to send via the currently selected endpoint.\r
+ *\r
+ * \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.\r
+ */\r
+ uint8_t Endpoint_Read_Control_EStream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1); \r
+\r
/* Private Interface - For use in library only: */\r
#if !defined(__DOXYGEN__)\r
/* Macros: */\r
#define _ENDPOINT_GET_DOUBLEBANK2(details) _ENDPOINT_GET_DOUBLEBANK3(details)\r
#define _ENDPOINT_GET_DOUBLEBANK3(maxsize, db) db\r
\r
- #if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER)\r
+ #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR)\r
#define ENDPOINT_DETAILS_EP0 64, true\r
#define ENDPOINT_DETAILS_EP1 256, true\r
#define ENDPOINT_DETAILS_EP2 64, true\r