Fixed PDI/TPI programming speed of ~250KHz in the AVRISP-MKII Clone project, instead...
[pub/USBasp.git] / LUFA / Drivers / USB / LowLevel / Endpoint.h
index eb4b616..ea2e8cc 100644 (file)
@@ -1,21 +1,21 @@
 /*
              LUFA Library
      Copyright (C) Dean Camera, 2010.
-              
+
   dean [at] fourwalledcubicle [dot] com
-      www.fourwalledcubicle.com
+           www.lufa-lib.org
 */
 
 /*
   Copyright 2010  Dean Camera (dean [at] fourwalledcubicle [dot] com)
 
-  Permission to use, copy, modify, distribute, and sell this 
+  Permission to use, copy, modify, distribute, and sell this
   software and its documentation for any purpose is hereby granted
-  without fee, provided that the above copyright notice appear in 
+  without fee, provided that the above copyright notice appear in
   all copies and that both that the copyright notice and this
-  permission notice and warranty disclaimer appear in supporting 
-  documentation, and that the name of the author not be used in 
-  advertising or publicity pertaining to distribution of the 
+  permission notice and warranty disclaimer appear in supporting
+  documentation, and that the name of the author not be used in
+  advertising or publicity pertaining to distribution of the
   software without specific, written prior permission.
 
   The author disclaim all warranties with regard to this
  *        dispatch header located in LUFA/Drivers/USB/USB.h.
  */
 
-/** \ingroup Group_USB
- *  @defgroup Group_EndpointManagement Endpoint Management
- *
- *  Functions, macros and enums related to endpoint management when in USB Device mode. This
- *  module contains the endpoint management macros, as well as endpoint interrupt and data
- *  send/receive functions for various data types.
- *
- *  @{
- */
-
-/** @defgroup Group_EndpointRW Endpoint Data Reading and Writing
+/** \ingroup Group_EndpointManagement
+ *  @defgroup Group_EndpointRW Endpoint Data Reading and Writing
  *
  *  Functions, macros, variables, enums and types related to data reading and writing from and to endpoints.
  */
-/** \ingroup Group_EndpointRW  
+
+/** \ingroup Group_EndpointRW
  *  @defgroup Group_EndpointPrimitiveRW Read/Write of Primitive Data Types
  *
  *  Functions, macros, variables, enums and types related to data reading and writing of primitive data types
  *  from and to endpoints.
- */ 
+ */
 
-/** \ingroup Group_EndpointRW  
- *  @defgroup Group_EndpointStreamRW Read/Write of Multi-Byte Streams
+/** \ingroup Group_EndpointManagement
+ *  @defgroup Group_EndpointPacketManagement Endpoint Packet Management
  *
- *  Functions, macros, variables, enums and types related to data reading and writing of data streams from
- *  and to endpoints.
- */ 
+ *  Functions, macros, variables, enums and types related to packet management of endpoints.
+ */
 
-/** @defgroup Group_EndpointPacketManagement Endpoint Packet Management
+/** \ingroup Group_USB
+ *  @defgroup Group_EndpointManagement Endpoint Management
  *
- *  Functions, macros, variables, enums and types related to packet management of endpoints.
+ *  Functions, macros and enums related to endpoint management when in USB Device mode. This
+ *  module contains the endpoint management macros, as well as endpoint interrupt and data
+ *  send/receive functions for various data types.
+ *
+ *  @{
  */
 
 #ifndef __ENDPOINT_H__
 
        /* Includes: */
                #include <avr/io.h>
-               #include <avr/pgmspace.h>
-               #include <avr/eeprom.h>
                #include <stdbool.h>
 
                #include "../../../Common/Common.h"
                #include "../HighLevel/USBTask.h"
                #include "USBInterrupt.h"
 
-               #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
-                       #include "../HighLevel/StreamCallbacks.h"
-               #endif
-               
        /* Enable C linkage for C++ Compilers: */
                #if defined(__cplusplus)
                        extern "C" {
                #if !defined(__INCLUDE_FROM_USB_DRIVER)
                        #error Do not include this file directly. Include LUFA/Drivers/USB/USB.h instead.
                #endif
-               
+
+       /* Private Interface - For use in library only: */
+       #if !defined(__DOXYGEN__)
+               /* Macros: */
+                       #define _ENDPOINT_GET_MAXSIZE(EPIndex)         _ENDPOINT_GET_MAXSIZE2(ENDPOINT_DETAILS_EP ## EPIndex)
+                       #define _ENDPOINT_GET_MAXSIZE2(EPDetails)      _ENDPOINT_GET_MAXSIZE3(EPDetails)
+                       #define _ENDPOINT_GET_MAXSIZE3(MaxSize, Banks) (MaxSize)
+
+                       #define _ENDPOINT_GET_BANKS(EPIndex)           _ENDPOINT_GET_BANKS2(ENDPOINT_DETAILS_EP ## EPIndex)
+                       #define _ENDPOINT_GET_BANKS2(EPDetails)        _ENDPOINT_GET_BANKS3(EPDetails)
+                       #define _ENDPOINT_GET_BANKS3(MaxSize, Banks)   (Banks)
+
+                       #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR)
+                               #define ENDPOINT_DETAILS_MAXEP             7
+
+                               #define ENDPOINT_DETAILS_EP0               64,  2
+                               #define ENDPOINT_DETAILS_EP1               256, 2
+                               #define ENDPOINT_DETAILS_EP2               64,  2
+                               #define ENDPOINT_DETAILS_EP3               64,  2
+                               #define ENDPOINT_DETAILS_EP4               64,  2
+                               #define ENDPOINT_DETAILS_EP5               64,  2
+                               #define ENDPOINT_DETAILS_EP6               64,  2
+                       #else
+                               #define ENDPOINT_DETAILS_MAXEP             5
+
+                               #define ENDPOINT_DETAILS_EP0               64,  2
+                               #define ENDPOINT_DETAILS_EP1               64,  1
+                               #define ENDPOINT_DETAILS_EP2               64,  1
+                               #define ENDPOINT_DETAILS_EP3               64,  2
+                               #define ENDPOINT_DETAILS_EP4               64,  2
+                       #endif
+
+               /* Inline Functions: */
+                       static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes) ATTR_WARN_UNUSED_RESULT ATTR_CONST
+                                                                                              ATTR_ALWAYS_INLINE;
+                       static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes)
+                       {
+                               uint8_t  MaskVal    = 0;
+                               uint16_t CheckBytes = 8;
+
+                               while (CheckBytes < Bytes)
+                               {
+                                       MaskVal++;
+                                       CheckBytes <<= 1;
+                               }
+
+                               return (MaskVal << EPSIZE0);
+                       }
+
+               /* Function Prototypes: */
+                       void Endpoint_ClearEndpoints(void);
+                       bool Endpoint_ConfigureEndpoint_Prv(const uint8_t Number,
+                                                           const uint8_t UECFG0XData,
+                                                           const uint8_t UECFG1XData);
+
+       #endif
+
        /* Public Interface - May be used in end-application: */
                /* Macros: */
+                       /** \name Endpoint Direction Masks */
+                       //@{
                        /** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
                         *  should be initialized in the OUT direction - i.e. data flows from host to device.
                         */
-                       #define ENDPOINT_DIR_OUT                      (0 << EPDIR)
+                       #define ENDPOINT_DIR_OUT                        (0 << EPDIR)
 
                        /** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
                         *  should be initialized in the IN direction - i.e. data flows from device to host.
                         */
-                       #define ENDPOINT_DIR_IN                       (1 << EPDIR)
-
+                       #define ENDPOINT_DIR_IN                         (1 << EPDIR)
+                       //@}
+                       
+                       /** \name Endpoint Bank Mode Masks */
+                       //@{
                        /** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
                         *  that the endpoint should have one single bank, which requires less USB FIFO memory but results
                         *  in slower transfers as only one USB device (the AVR or the host) can access the endpoint's
                         *  bank at the one time.
                         */
-                       #define ENDPOINT_BANK_SINGLE                  (0 << EPBK0)
+                       #define ENDPOINT_BANK_SINGLE                    (0 << EPBK0)
 
                        /** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
                         *  that the endpoint should have two banks, which requires more USB FIFO memory but results
                         *  in faster transfers as one USB device (the AVR or the host) can access one bank while the other
                         *  accesses the second bank.
                         */
-                       #define ENDPOINT_BANK_DOUBLE                  (1 << EPBK0)
+                       #define ENDPOINT_BANK_DOUBLE                    (1 << EPBK0)
+                       //@}
                        
                        /** Endpoint address for the default control endpoint, which always resides in address 0. This is
                         *  defined for convenience to give more readable code when used with the endpoint macros.
                         */
-                       #define ENDPOINT_CONTROLEP                    0
+                       #define ENDPOINT_CONTROLEP                      0
 
                        #if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
-                               /** Default size of the default control endpoint's bank, until altered by the control endpoint bank size 
+                               /** Default size of the default control endpoint's bank, until altered by the control endpoint bank size
                                 *  value in the device descriptor. Not available if the FIXED_CONTROL_ENDPOINT_SIZE token is defined.
                                 */
-                               #define ENDPOINT_CONTROLEP_DEFAULT_SIZE   8
+                               #define ENDPOINT_CONTROLEP_DEFAULT_SIZE     8
                        #endif
-                       
+
                        /** Endpoint number mask, for masking against endpoint addresses to retrieve the endpoint's
                         *  numerical address in the device.
                         */
-                       #define ENDPOINT_EPNUM_MASK                   0x07
+                       #define ENDPOINT_EPNUM_MASK                     0x07
 
                        /** Endpoint direction mask, for masking against endpoint addresses to retrieve the endpoint's
                         *  direction for comparing with the ENDPOINT_DESCRIPTOR_DIR_* masks.
                         */
-                       #define ENDPOINT_EPDIR_MASK                   0x80
+                       #define ENDPOINT_EPDIR_MASK                     0x80
 
                        /** Endpoint bank size mask, for masking against endpoint addresses to retrieve the endpoint's
                         *  bank size in the device.
                         */
-                       #define ENDPOINT_EPSIZE_MASK                  0x7F
-                       
+                       #define ENDPOINT_EPSIZE_MASK                    0x7F
+
                        /** Maximum size in bytes of a given endpoint.
                         *
-                        *  \param[in] n  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
-                        */                             
-                       #define ENDPOINT_MAX_SIZE(n)                  _ENDPOINT_GET_MAXSIZE(n)
+                        *  \param[in] EPIndex  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
+                        */
+                       #define ENDPOINT_MAX_SIZE(EPIndex)              _ENDPOINT_GET_MAXSIZE(EPIndex)
 
-                       /** Indicates if the given endpoint supports double banking.
+                       /** Indicates the total number of banks supported by the given endpoint.
                         *
-                        *  \param[in] n  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
-                        */                             
-                       #define ENDPOINT_DOUBLEBANK_SUPPORTED(n)      _ENDPOINT_GET_DOUBLEBANK(n)
+                        *  \param[in] EPIndex  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
+                        */
+                       #define ENDPOINT_BANKS_SUPPORTED(EPIndex)       _ENDPOINT_GET_BANKS(EPIndex)
 
-                       #if !defined(CONTROL_ONLY_DEVICE)
-                               #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR) || defined(__DOXYGEN__)
-                                       /** Total number of endpoints (including the default control endpoint at address 0) which may
-                                        *  be used in the device. Different USB AVR models support different amounts of endpoints,
-                                        *  this value reflects the maximum number of endpoints for the currently selected AVR model.
-                                        */
-                                       #define ENDPOINT_TOTAL_ENDPOINTS      7
-                               #else
-                                       #define ENDPOINT_TOTAL_ENDPOINTS      5
-                               #endif
+                       #if !defined(CONTROL_ONLY_DEVICE) || defined(__DOXYGEN__)
+                               /** Total number of endpoints (including the default control endpoint at address 0) which may
+                                *  be used in the device. Different USB AVR models support different amounts of endpoints,
+                                *  this value reflects the maximum number of endpoints for the currently selected AVR model.
+                                */
+                               #define ENDPOINT_TOTAL_ENDPOINTS            ENDPOINT_DETAILS_MAXEP
                        #else
-                               #define ENDPOINT_TOTAL_ENDPOINTS          1
+                               #define ENDPOINT_TOTAL_ENDPOINTS            1
                        #endif
 
                /* Enums: */
                                                                                 *   \ref USB_STREAM_TIMEOUT_MS macro.
                                                                                 */
                        };
-               
-                       /** Enum for the possible error return codes of the Endpoint_*_Stream_* functions.
+
+               /* Inline Functions: */
+                       /** Configures the specified endpoint number with the given endpoint type, direction, bank size
+                        *  and banking mode. Once configured, the endpoint may be read from or written to, depending
+                        *  on its direction.
                         *
-                        *  \ingroup Group_EndpointStreamRW
-                        */
-                       enum Endpoint_Stream_RW_ErrorCodes_t
-                       {
-                               ENDPOINT_RWSTREAM_NoError            = 0, /**< Command completed successfully, no error. */
-                               ENDPOINT_RWSTREAM_EndpointStalled    = 1, /**< The endpoint was stalled during the stream
-                                                                          *   transfer by the host or device.
-                                                                          */
-                               ENDPOINT_RWSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during
-                                                                          *   the transfer.
-                                                                          */
-                               ENDPOINT_RWSTREAM_BusSuspended       = 3, /**< The USB bus has been suspended by the host and
-                                                                          *   no USB endpoint traffic can occur until the bus
-                                                                          *   has resumed.
-                                                                          */
-                               ENDPOINT_RWSTREAM_Timeout            = 4, /**< The host failed to accept or send the next packet
-                                                                          *   within the software timeout period set by the
-                                                                          *   \ref USB_STREAM_TIMEOUT_MS macro.
-                                                                          */
-                               ENDPOINT_RWSTREAM_CallbackAborted    = 5, /**< Indicates that the stream's callback function
-                                                                      *   aborted the transfer early.
-                                                                          */
-                       };
-                       
-                       /** Enum for the possible error return codes of the Endpoint_*_Control_Stream_* functions..
+                        *  \param[in] Number     Endpoint number to configure. This must be more than 0 and less than
+                        *                        \ref ENDPOINT_TOTAL_ENDPOINTS.
                         *
-                        *  \ingroup Group_EndpointStreamRW
+                        *  \param[in] Type       Type of endpoint to configure, a EP_TYPE_* mask. Not all endpoint types
+                        *                        are available on Low Speed USB devices - refer to the USB 2.0 specification.
+                        *
+                        *  \param[in] Direction  Endpoint data direction, either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.
+                        *                        All endpoints (except Control type) are unidirectional - data may only be read
+                        *                        from or written to the endpoint bank based on its direction, not both.
+                        *
+                        *  \param[in] Size       Size of the endpoint's bank, where packets are stored before they are transmitted
+                        *                        to the USB host, or after they have been received from the USB host (depending on
+                        *                        the endpoint's data direction). The bank size must indicate the maximum packet size
+                        *                        that the endpoint can handle.
+                        *
+                        *  \param[in] Banks      Number of banks to use for the endpoint being configured, an ENDPOINT_BANK_* mask.
+                        *                        More banks uses more USB DPRAM, but offers better performance. Isochronous type
+                        *                        endpoints <b>must</b> have at least two banks.
+                        *
+                        *  \note Endpoints <b>must</b> be configured in ascending order, or bank corruption will occur.
+                        *        \n\n
+                        *
+                        *  \note Certain models of USB AVR's endpoints may have different maximum packet sizes based on the endpoint's
+                        *        index - refer to the chosen USB AVR's datasheet to determine the maximum bank size for each endpoint.
+                        *        \n\n
+                        *
+                        *  \note The default control endpoint should not be manually configured by the user application, as
+                        *        it is automatically configured by the library internally.
+                        *        \n\n
+                        *
+                        *  \note This routine will automatically select the specified endpoint upon success. Upon failure, the endpoint
+                        *        which failed to reconfigure correctly will be selected.
+                        *
+                        *  \return Boolean true if the configuration succeeded, false otherwise.
                         */
-                       enum Endpoint_ControlStream_RW_ErrorCodes_t
+                       static inline bool Endpoint_ConfigureEndpoint(const uint8_t Number,
+                                                                     const uint8_t Type,
+                                                                     const uint8_t Direction,
+                                                                     const uint16_t Size,
+                                                                     const uint8_t Banks) ATTR_ALWAYS_INLINE;
+                       static inline bool Endpoint_ConfigureEndpoint(const uint8_t Number,
+                                                                     const uint8_t Type,
+                                                                     const uint8_t Direction,
+                                                                     const uint16_t Size,
+                                                                     const uint8_t Banks)
                        {
-                               ENDPOINT_RWCSTREAM_NoError            = 0, /**< Command completed successfully, no error. */
-                               ENDPOINT_RWCSTREAM_HostAborted        = 1, /**< The aborted the transfer prematurely. */
-                               ENDPOINT_RWCSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during
-                                                                           *   the transfer.
-                                                                           */
-                               ENDPOINT_RWCSTREAM_BusSuspended       = 3, /**< The USB bus has been suspended by the host and
-                                                                           *   no USB endpoint traffic can occur until the bus
-                                                                           *   has resumed.
-                                                                           */
-                       };
+                               return Endpoint_ConfigureEndpoint_Prv(Number, (((Type) << EPTYPE0) | (Direction)),
+                                                                     ((1 << ALLOC) | Banks | Endpoint_BytesToEPSizeMask(Size)));
+                       }
 
-               /* Inline Functions: */
                        /** Indicates the number of bytes currently stored in the current endpoint's selected bank.
                         *
                         *  \note The return width of this function may differ, depending on the maximum endpoint bank size
                                        return UEBCLX;
                                #endif
                        }
-               
+
                        /** Get the endpoint address of the currently selected endpoint. This is typically used to save
                         *  the currently selected endpoint number so that it can be restored after another endpoint has
                         *  been manipulated.
                                        return ENDPOINT_CONTROLEP;
                                #endif
                        }
-                       
+
                        /** Selects the given endpoint number. If the address from the device descriptors is used, the
                         *  value should be masked with the \ref ENDPOINT_EPNUM_MASK constant to extract only the endpoint
                         *  number (and discarding the endpoint direction bit).
                        {
                                #if !defined(CONTROL_ONLY_DEVICE)
                                        UENUM = EndpointNumber;
-                               #endif                  
+                               #endif
                        }
-                       
+
                        /** Resets the endpoint bank FIFO. This clears all the endpoint banks and resets the USB controller's
                         *  In and Out pointers to the bank's contents.
                         *
                                UERST = (1 << EndpointNumber);
                                UERST = 0;
                        }
-                       
+
                        /** Enables the currently selected endpoint so that data can be sent and received through it to
                         *  and from a host.
                         *
                        {
                                UECONX &= ~(1 << EPEN);
                        }
-                       
+
                        /** Determines if the currently selected endpoint is enabled, but not necessarily configured.
                         *
                         * \return Boolean True if the currently selected endpoint is enabled, false otherwise.
                        {
                                return ((UECONX & (1 << EPEN)) ? true : false);
                        }
+
+                       /** Aborts all pending IN transactions on the currently selected endpoint, once the bank
+                        *  has been queued for transmission to the host via \ref Endpoint_ClearIN(). This function
+                        *  will terminate all queued transactions, resetting the endpoint banks ready for a new
+                        *  packet.
+                        *
+                        *  \ingroup Group_EndpointPacketManagement
+                        */
+                       static inline void Endpoint_AbortPendingIN(void)
+                       {
+                               while (UESTA0X & (0x03 << NBUSYBK0))
+                               {
+                                       UEINTX |= (1 << RXOUTI);
+                                       while (UEINTX & (1 << RXOUTI));
+                               }
+                       }
                        
+                       /** Retrieves the number of busy banks in the currently selected endpoint, which have been queued for
+                        *  transmission via the \ref Endpoint_ClearIN() command, or are awaiting acknowledgement via the
+                        *  \ref Endpoint_ClearOUT() command.
+                        *
+                        *  \ingroup Group_EndpointPacketManagement
+                        *
+                        *  \return Total number of busy banks in the selected endpoint.
+                        */
+                       static inline uint8_t Endpoint_GetBusyBanks(void)
+                       {
+                               return (UESTA0X & (0x03 << NBUSYBK0));
+                       }
+
                        /** Determines if the currently selected endpoint may be read from (if data is waiting in the endpoint
                         *  bank and the endpoint is an OUT direction, or if the bank is not yet full if the endpoint is an IN
                         *  direction). This function will return false if an error has occurred in the endpoint, if the endpoint
                        {
                                return ((UEINTX & (1 << RWAL)) ? true : false);
                        }
-                       
+
                        /** Determines if the currently selected endpoint is configured.
                         *
                         *  \return Boolean true if the currently selected endpoint has been configured, false otherwise.
                        {
                                return ((UESTA0X & (1 << CFGOK)) ? true : false);
                        }
-                       
+
                        /** Returns a mask indicating which INTERRUPT type endpoints have interrupted - i.e. their
                         *  interrupt duration has elapsed. Which endpoints have interrupted can be determined by
                         *  masking the return value against (1 << {Endpoint Number}).
                        {
                                return UEINT;
                        }
-                       
+
                        /** Determines if the specified endpoint number has interrupted (valid only for INTERRUPT type
                         *  endpoints).
                         *
                        {
                                return ((UEINT & (1 << EndpointNumber)) ? true : false);
                        }
-                       
-                       /** Determines if the selected IN endpoint is ready for a new packet.
+
+                       /** Determines if the selected IN endpoint is ready for a new packet to be sent to the host.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                         *
                        static inline bool Endpoint_IsINReady(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
                        static inline bool Endpoint_IsINReady(void)
                        {
-                               return ((UEINTX & (1 << TXINI))  ? true : false);
+                               return ((UEINTX & (1 << TXINI)) ? true : false);
                        }
-                       
-                       /** Determines if the selected OUT endpoint has received new packet.
+
+                       /** Determines if the selected OUT endpoint has received new packet from the host.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                         *
                        {
                                return ((UEINTX & (1 << RXOUTI)) ? true : false);
                        }
-                       
+
                        /** Determines if the current CONTROL type endpoint has received a SETUP packet.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                        {
                                return ((UEINTX & (1 << RXSTPI)) ? true : false);
                        }
-                       
+
                        /** Clears a received SETUP packet on the currently selected CONTROL type endpoint, freeing up the
                         *  endpoint for the next packet.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                         *
-                        *  \note This is not applicable for non CONTROL type endpoints. 
+                        *  \note This is not applicable for non CONTROL type endpoints.
                         */
                        static inline void Endpoint_ClearSETUP(void) ATTR_ALWAYS_INLINE;
                        static inline void Endpoint_ClearSETUP(void)
                        {
                                UEINTX &= ~(1 << RXSTPI);
                        }
-                       
+
                        /** Sends an IN packet to the host on the currently selected endpoint, freeing up the endpoint for the
                         *  next packet and switching to the alternative endpoint bank if double banked.
                         *
                                        UEINTX &= ~(1 << TXINI);
                                #endif
                        }
-                       
+
                        /** Acknowledges an OUT packet to the host on the currently selected endpoint, freeing up the endpoint
                         *  for the next packet and switching to the alternative endpoint bank if double banked.
                         *
                                #if !defined(CONTROL_ONLY_DEVICE)
                                        UEINTX &= ~((1 << RXOUTI) | (1 << FIFOCON));
                                #else
-                                       UEINTX &= ~(1 << RXOUTI);       
+                                       UEINTX &= ~(1 << RXOUTI);
                                #endif
                        }
-                       
+
                        /** Stalls the current endpoint, indicating to the host that a logical problem occurred with the
                         *  indicated endpoint and that the current transfer sequence should be aborted. This provides a
                         *  way for devices to indicate invalid commands to the host so that the current transfer can be
                        {
                                UECONX |= (1 << STALLRQ);
                        }
-                       
+
                        /** Clears the STALL condition on the currently selected endpoint.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                        {
                                UECONX |= (1 << STALLRQC);
                        }
-                       
+
                        /** Determines if the currently selected endpoint is stalled, false otherwise.
                         *
                         *  \ingroup Group_EndpointPacketManagement
                        {
                                return ((UECONX & (1 << STALLRQ)) ? true : false);
                        }
-                       
+
                        /** Resets the data toggle of the currently selected endpoint. */
                        static inline void Endpoint_ResetDataToggle(void) ATTR_ALWAYS_INLINE;
                        static inline void Endpoint_ResetDataToggle(void)
                        {
                                UECONX |= (1 << RSTDT);
                        }
-                       
+
                        /** Determines the currently selected endpoint's direction.
                         *
                         *  \return The currently selected endpoint's direction, as a ENDPOINT_DIR_* mask.
                        static inline void Endpoint_Discard_Byte(void)
                        {
                                uint8_t Dummy;
-                               
+
                                Dummy = UEDATX;
                        }
-                       
+
                        /** Reads two bytes from the currently selected endpoint's bank in little endian format, for OUT
                         *  direction endpoints.
                         *
                                        uint16_t Word;
                                        uint8_t  Bytes[2];
                                } Data;
-                               
+
                                Data.Bytes[0] = UEDATX;
                                Data.Bytes[1] = UEDATX;
-                       
+
                                return Data.Word;
                        }
 
                                        uint16_t Word;
                                        uint8_t  Bytes[2];
                                } Data;
-                               
+
                                Data.Bytes[1] = UEDATX;
                                Data.Bytes[0] = UEDATX;
-                       
+
                                return Data.Word;
                        }
 
                                UEDATX = (Word & 0xFF);
                                UEDATX = (Word >> 8);
                        }
-                       
+
                        /** Writes two bytes to the currently selected endpoint's bank in big endian format, for IN
                         *  direction endpoints.
                         *
                        static inline void Endpoint_Discard_Word(void)
                        {
                                uint8_t Dummy;
-                               
+
                                Dummy = UEDATX;
                                Dummy = UEDATX;
                        }
                                        uint32_t DWord;
                                        uint8_t  Bytes[4];
                                } Data;
-                               
+
                                Data.Bytes[0] = UEDATX;
                                Data.Bytes[1] = UEDATX;
                                Data.Bytes[2] = UEDATX;
                                Data.Bytes[3] = UEDATX;
-                       
+
                                return Data.DWord;
                        }
 
                                        uint32_t DWord;
                                        uint8_t  Bytes[4];
                                } Data;
-                               
+
                                Data.Bytes[3] = UEDATX;
                                Data.Bytes[2] = UEDATX;
                                Data.Bytes[1] = UEDATX;
                                Data.Bytes[0] = UEDATX;
-                       
+
                                return Data.DWord;
                        }
 
                                UEDATX = (DWord >> 16);
                                UEDATX = (DWord >> 24);
                        }
-                       
+
                        /** Writes four bytes to the currently selected endpoint's bank in big endian format, for IN
                         *  direction endpoints.
                         *
                                UEDATX = (DWord &  0xFF);
                        }
 
-                       /** Discards four bytes from the currently selected endpoint's bank, for OUT direction endpoints.       
+                       /** Discards four bytes from the currently selected endpoint's bank, for OUT direction endpoints.
                         *
                         *  \ingroup Group_EndpointPrimitiveRW
                         */
                        static inline void Endpoint_Discard_DWord(void)
                        {
                                uint8_t Dummy;
-                               
+
                                Dummy = UEDATX;
                                Dummy = UEDATX;
                                Dummy = UEDATX;
                        #endif
 
                /* Function Prototypes: */
-                       #if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
-                               #define __CALLBACK_PARAM     , StreamCallbackPtr_t Callback
-                       #else
-                               #define __CALLBACK_PARAM
-                       #endif
-               
-                       /** Configures the specified endpoint number with the given endpoint type, direction, bank size
-                        *  and banking mode. Endpoints should be allocated in ascending order by their address in the
-                        *  device (i.e. endpoint 1 should be configured before endpoint 2 and so on) to prevent fragmentation
-                        *  of the USB FIFO memory.
-                        *
-                        *  The endpoint type may be one of the EP_TYPE_* macros listed in LowLevel.h and the direction
-                        *  may be either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.
-                        *
-                        *  The bank size must indicate the maximum packet size that the endpoint can handle. Different
-                        *  endpoint numbers can handle different maximum packet sizes - refer to the chosen USB AVR's
-                        *  datasheet to determine the maximum bank size for each endpoint.
-                        *
-                        *  The banking mode may be either \ref ENDPOINT_BANK_SINGLE or \ref ENDPOINT_BANK_DOUBLE.
-                        *
-                        *  \note The default control endpoint should not be manually configured by the user application, as 
-                        *        it is automatically configured by the library internally.
-                        *        \n\n
-                        *
-                        *  \note This routine will select the specified endpoint, and the endpoint will remain selected
-                        *        once the routine completes regardless of if the endpoint configuration succeeds.
-                        *
-                        *  \return Boolean true if the configuration succeeded, false otherwise.
+                       /** Completes the status stage of a control transfer on a CONTROL type endpoint automatically,
+                        *  with respect to the data direction. This is a convenience function which can be used to
+                        *  simplify user control request handling.
                         */
-                       bool Endpoint_ConfigureEndpoint(const uint8_t  Number,
-                                                       const uint8_t Type,
-                                                       const uint8_t Direction,
-                                                       const uint16_t Size,
-                                                       const uint8_t Banks);
+                       void Endpoint_ClearStatusStage(void);
 
                        /** Spin-loops until the currently selected non-control endpoint is ready for the next packet of data
                         *  to be read or written to it.
                         *  \return A value from the \ref Endpoint_WaitUntilReady_ErrorCodes_t enum.
                         */
                        uint8_t Endpoint_WaitUntilReady(void);
-                       
-                       /** Completes the status stage of a control transfer on a CONTROL type endpoint automatically,
-                        *  with respect to the data direction. This is a convenience function which can be used to
-                        *  simplify user control request handling.
-                        */
-                       void Endpoint_ClearStatusStage(void);
-
-                       /** Reads and discards the given number of bytes from the endpoint from the given buffer,
-                        *  discarding fully read packets from the host as needed. The last packet is not automatically
-                        *  discarded once the remaining bytes has been read; the user is responsible for manually
-                        *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
-                        *  each USB packet, the given stream callback function is executed repeatedly until the next
-                        *  packet is ready, allowing for early aborts of stream transfers.
-                        *
-                        *      The callback routine should be created according to the information in \ref Group_StreamCallbacks.
-                        *  If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
-                        *  disabled and this function has the Callback parameter omitted.
-                        *
-                        *  \note This routine should not be used on CONTROL type endpoints.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Length    Number of bytes to send via the currently selected endpoint.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Discard_Stream(uint16_t Length
-                                                       __CALLBACK_PARAM);
-
-                       /** Writes the given number of bytes to the endpoint from the given buffer in little endian,
-                        *  sending full packets to the host as needed. The last packet filled is not automatically sent;
-                        *  the user is responsible for manually sending the last written packet to the host via the
-                        *  \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
-                        *  is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
-                        *  aborts of stream transfers.
-                        *
-                        *      The callback routine should be created according to the information in \ref Group_StreamCallbacks.
-                        *  If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
-                        *  disabled and this function has the Callback parameter omitted.
-                        *
-                        *  \note This routine should not be used on CONTROL type endpoints.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Stream_LE(const void* Buffer,
-                                                        uint16_t Length
-                                                        __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Write_Stream_LE().
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_EStream_LE(const void* Buffer,
-                                                         uint16_t Length
-                                                         __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** FLASH buffer source version of \ref Endpoint_Write_Stream_LE().
-                        *
-                        *  \pre The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_PStream_LE(const void* Buffer,
-                                                         uint16_t Length
-                                                         __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Writes the given number of bytes to the endpoint from the given buffer in big endian,
-                        *  sending full packets to the host as needed. The last packet filled is not automatically sent;
-                        *  the user is responsible for manually sending the last written packet to the host via the
-                        *  \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
-                        *  is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
-                        *  aborts of stream transfers.
-                        *
-                        *      The callback routine should be created according to the information in \ref Group_StreamCallbacks.
-                        *  If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
-                        *  disabled and this function has the Callback parameter omitted.
-                        *
-                        *  \note This routine should not be used on CONTROL type endpoints.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Stream_BE(const void* Buffer,
-                                                        uint16_t Length
-                                                        __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Write_Stream_BE().
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_EStream_BE(const void* Buffer,
-                                                         uint16_t Length
-                                                         __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** FLASH buffer source version of \ref Endpoint_Write_Stream_BE().
-                        *
-                        *  \pre The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer    Pointer to the source data buffer to read from.
-                        *  \param[in] Length    Number of bytes to read for the currently selected endpoint into the buffer.
-                        *  \param[in] Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_PStream_BE(const void* Buffer,
-                                                         uint16_t Length
-                                                         __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Reads the given number of bytes from the endpoint from the given buffer in little endian,
-                        *  discarding fully read packets from the host as needed. The last packet is not automatically
-                        *  discarded once the remaining bytes has been read; the user is responsible for manually
-                        *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
-                        *  each USB packet, the given stream callback function is executed repeatedly until the endpoint
-                        *  is ready to accept the next packet, allowing for early aborts of stream transfers.
-                        *
-                        *      The callback routine should be created according to the information in \ref Group_StreamCallbacks.
-                        *  If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
-                        *  disabled and this function has the Callback parameter omitted.
-                        *
-                        *  \note This routine should not be used on CONTROL type endpoints.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer    Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length    Number of bytes to send via the currently selected endpoint.
-                        *  \param[in]  Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Stream_LE(void* Buffer,
-                                                       uint16_t Length
-                                                       __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Read_Stream_LE().
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer    Pointer to the destination data buffer to write to, located in EEPROM memory space.
-                        *  \param[in]  Length    Number of bytes to send via the currently selected endpoint.
-                        *  \param[in]  Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_EStream_LE(void* Buffer,
-                                                        uint16_t Length
-                                                        __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-                       
-                       /** Reads the given number of bytes from the endpoint from the given buffer in big endian,
-                        *  discarding fully read packets from the host as needed. The last packet is not automatically
-                        *  discarded once the remaining bytes has been read; the user is responsible for manually
-                        *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
-                        *  each USB packet, the given stream callback function is executed repeatedly until the endpoint
-                        *  is ready to accept the next packet, allowing for early aborts of stream transfers.
-                        *
-                        *      The callback routine should be created according to the information in \ref Group_StreamCallbacks.
-                        *  If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
-                        *  disabled and this function has the Callback parameter omitted.
-                        *
-                        *  \note This routine should not be used on CONTROL type endpoints.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer    Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length    Number of bytes to send via the currently selected endpoint.
-                        *  \param[in]  Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Stream_BE(void* Buffer,
-                                                       uint16_t Length
-                                                       __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Read_Stream_BE().
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer    Pointer to the destination data buffer to write to, located in EEPROM memory space.
-                        *  \param[in]  Length    Number of bytes to send via the currently selected endpoint.
-                        *  \param[in]  Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback.
-                        *
-                        *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_EStream_BE(void* Buffer,
-                                                        uint16_t Length
-                                                        __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,
-                        *  sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
-                        *  in both failure and success states; the user is responsible for manually clearing the setup OUT to
-                        *  finalize the transfer via the \ref Endpoint_ClearOUT() macro.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_Stream_LE(const void* Buffer,
-                                                                uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of Endpoint_Write_Control_Stream_LE.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_EStream_LE(const void* Buffer,
-                                                                 uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_LE().
-                        *
-                        *  \pre The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_PStream_LE(const void* Buffer,
-                                                                 uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,
-                        *  sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
-                        *  in both failure and success states; the user is responsible for manually clearing the setup OUT to
-                        *  finalize the transfer via the \ref Endpoint_ClearOUT() macro.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_Stream_BE(const void* Buffer,
-                                                                uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Write_Control_Stream_BE().
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_EStream_BE(const void* Buffer,
-                                                                 uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_BE().
-                        *
-                        *  \pre The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[in] Buffer  Pointer to the source data buffer to read from.
-                        *  \param[in] Length  Number of bytes to read for the currently selected endpoint into the buffer.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Write_Control_PStream_BE(const void* Buffer,
-                                                                 uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,
-                        *  discarding fully read packets from the host as needed. The device IN acknowledgement is not
-                        *  automatically sent after success or failure states; the user is responsible for manually sending the
-                        *  setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer  Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length  Number of bytes to send via the currently selected endpoint.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Control_Stream_LE(void* Buffer,
-                                                               uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_LE().
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer  Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length  Number of bytes to send via the currently selected endpoint.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Control_EStream_LE(void* Buffer,
-                                                                uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-                       /** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,
-                        *  discarding fully read packets from the host as needed. The device IN acknowledgement is not
-                        *  automatically sent after success or failure states; the user is responsible for manually sending the
-                        *  setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer  Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length  Number of bytes to send via the currently selected endpoint.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Control_Stream_BE(void* Buffer,
-                                                               uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-                       
-                       /** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_BE().
-                        *
-                        *  \note This function automatically clears the control transfer's status stage. Do not manually attempt
-                        *        to clear the status stage when using this routine in a control transaction.
-                        *        \n\n
-                        *
-                        *  \note This routine should only be used on CONTROL type endpoints.
-                        *
-                        *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
-                        *           together; i.e. the entire stream data must be read or written at the one time.
-                        *
-                        *  \ingroup Group_EndpointStreamRW
-                        *
-                        *  \param[out] Buffer  Pointer to the destination data buffer to write to.
-                        *  \param[in]  Length  Number of bytes to send via the currently selected endpoint.
-                        *
-                        *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
-                        */
-                       uint8_t Endpoint_Read_Control_EStream_BE(void* Buffer,
-                                                                uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
-
-       /* Private Interface - For use in library only: */
-       #if !defined(__DOXYGEN__)
-               /* Macros: */
-                       #define _ENDPOINT_GET_MAXSIZE(n)               _ENDPOINT_GET_MAXSIZE2(ENDPOINT_DETAILS_EP ## n)
-                       #define _ENDPOINT_GET_MAXSIZE2(details)        _ENDPOINT_GET_MAXSIZE3(details)
-                       #define _ENDPOINT_GET_MAXSIZE3(maxsize, db)    maxsize
-
-                       #define _ENDPOINT_GET_DOUBLEBANK(n)            _ENDPOINT_GET_DOUBLEBANK2(ENDPOINT_DETAILS_EP ## n)
-                       #define _ENDPOINT_GET_DOUBLEBANK2(details)     _ENDPOINT_GET_DOUBLEBANK3(details)
-                       #define _ENDPOINT_GET_DOUBLEBANK3(maxsize, db) db
-                       
-                       #if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR)
-                               #define ENDPOINT_DETAILS_EP0               64,  true
-                               #define ENDPOINT_DETAILS_EP1               256, true
-                               #define ENDPOINT_DETAILS_EP2               64,  true
-                               #define ENDPOINT_DETAILS_EP3               64,  true
-                               #define ENDPOINT_DETAILS_EP4               64,  true
-                               #define ENDPOINT_DETAILS_EP5               64,  true
-                               #define ENDPOINT_DETAILS_EP6               64,  true
-                       #else
-                               #define ENDPOINT_DETAILS_EP0               64,  true
-                               #define ENDPOINT_DETAILS_EP1               64,  false
-                               #define ENDPOINT_DETAILS_EP2               64,  false
-                               #define ENDPOINT_DETAILS_EP3               64,  true
-                               #define ENDPOINT_DETAILS_EP4               64,  true                    
-                       #endif
-
-                       #define Endpoint_ConfigureEndpoint(Number, Type, Direction, Size, Banks)                           \
-                                            (__builtin_constant_p(Size) ? Endpoint_ConfigureEndpointStatic((Number),      \
-                                                                                                           (Type),        \
-                                                                                                           (Direction),   \
-                                                                                                           Size, Banks) : \
-                                                                          Endpoint_ConfigureEndpointDynamic((Number),     \
-                                                                                                            (Type),       \
-                                                                                                            (Direction),  \
-                                                                                                            Size, Banks))
-
-               /* Function Prototypes: */
-                       void    Endpoint_ClearEndpoints(void);
-                       uint8_t Endpoint_BytesToEPSizeMaskDynamic(const uint16_t Size);
-                       bool    Endpoint_ConfigureEndpoint_Prv(const uint8_t Number,
-                                                              const uint8_t UECFG0XData,
-                                                              const uint8_t UECFG1XData);                      
-
-               /* Inline Functions: */
-                       static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes) ATTR_WARN_UNUSED_RESULT ATTR_CONST ATTR_ALWAYS_INLINE;
-                       static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes)
-                       {
-                               uint8_t  MaskVal    = 0;
-                               uint16_t CheckBytes = 8;
-                               
-                               while (CheckBytes < Bytes)
-                               {
-                                       MaskVal++;
-                                       CheckBytes <<= 1;
-                               }
-                               
-                               return (MaskVal << EPSIZE0);
-                       }
-                       
-                       static inline bool Endpoint_ConfigureEndpointStatic(const uint8_t Number,
-                                                                           const uint8_t Type,
-                                                                           const uint8_t Direction,
-                                                                           const uint16_t Size,
-                                                                           const uint8_t Banks)
-                       {
-                               return Endpoint_ConfigureEndpoint_Prv(Number, (((Type) << EPTYPE0) | (Direction)),
-                                                                     ((1 << ALLOC) | Banks | Endpoint_BytesToEPSizeMask(Size)));
-                       }
-
-                       static inline bool Endpoint_ConfigureEndpointDynamic(const uint8_t Number,
-                                                                            const uint8_t Type,
-                                                                            const uint8_t Direction,
-                                                                            const uint16_t Size,
-                                                                            const uint8_t Banks)
-                       {
-                               return Endpoint_ConfigureEndpoint_Prv(Number, (((Type) << EPTYPE0) | (Direction)),
-                                                                     ((1 << ALLOC) | Banks | Endpoint_BytesToEPSizeMaskDynamic(Size)));
-                       }
-       #endif
 
        /* Disable C linkage for C++ Compilers: */
                #if defined(__cplusplus)
                        }
                #endif
-               
+
 #endif
 
 /** @} */
+